Proheat M80 Manuel de service Page 50

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 90
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 49
Fuel Solenoid Valve Check:
a) Valve plunger mechanical fault. Test the PROHEAT operation; Fuel
Solenoid Valve plunger removed.
Procedure Fuel Solenoid Valve Mechanical Function:
a) Disconnect all harnesses at the G-II PCM.
b) Disconnect the fuel supply line.
c) Loosen and back out the burner head mounting (2) bolts five to six turns
allowing enough room to rotate the burner head 15° counter-clockwise
and remove.
d) Remove the Fuel Solenoid Valve connector. Use a small flat head
screwdriver to lift the connector locking tab, pulling up on the
connector to remove.
START: Fuel System Step 5
(1 Flash)
Figure 4-14: G-II PCM Fuel Solenoid Valve Connection.
G-II PCM FUEL SOLENOID
VALVE CONNECTION
NOTICE
It is recommended that the Fuel
R
egulator be serviced at the same
time as the Fuel Solenoid Valve. Go
to page 4-15, Step 6.
Figure 4-12: Burner Head Removal.
MOUNTING EARS (2)
MOUNTING BOLTS (2)
TORQUE = SEE SECTION 1.3
COOLANT PUMP
SWITCH INPUT
TEMP SENSOR 1
POWER
FUEL INLET
LOCK
Figure 4-13: Connector Removal.
4-13
PROHEAT M-SERIES G-II PCM SERVICE MANUAL
Vue de la page 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 89 90